Designation Of Sensors - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
9.3

Designation of sensors

The sensor designations are coded as follows.
Pos: 73 /Sc hweis snaht/ Senso ren/ Senso rbeze ich nung/Komb isens oren (W irbe lst rom/Streuf lus s) @ 0\mod_ 112 9638 403 421 _501. docx @ 868 @ 3 @ 1
9.3.1
Combination sensors (leakage flux / eddy current)
Measuring principle 1:
NS = Seam sensor
(Standard meas.
principle = leakage flux)
Type of enclosure:
9 = type 9
12 = type 12
Pos: 74 /Sc hweis snaht/ Senso ren/ Senso rbeze ich nung/W irbe lst romse nso ren @ 0\mod _11 296 3854 475 0_5 01.docx @ 871 @ 3 @ 1
9.3.2
Eddy current sensors
Measuring principle:
EC = eddy current
Type of enclosure
9 = type 9
12 = type 12
Pos: 75 /Sc hweis snaht/ Senso ren/ Senso rbeze ich nung/W irbe lst romso nden @ 0\mod_1 129 6386 460 78_ 501.do cx @ 87 4 @ 3 @ 1
9.3.3
Eddy current probes / Eddy current coils
Measuring principle:
EC = Eddy current
Dimensions of probe:
12x40 = diam. 12mm, length 40mm
20x25 = diam. 20mm, length 25mm
Pos: 76 /Sc hweis snaht/ Senso ren/N S9/N S9 S Tec hni sche Da ten @ 0\mo d_1 1212 635 217 34_5 01.do cx @ 56 9 @ 2 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Measuring principle 2:
Material of enclosure:
EC = Eddy current
N = Aluminium, nickel plated
NS9-EC8x60NT10-100-SC
Dimensions of sensor element:
8x60 = width 8mm, length 60mm
8x80 = width 8mm, length 80mm
Material of enclosure:
N = Aluminium, nickel plated
EC9-8x60NT10-100-SC
Dimensions of sensor element:
8x60 = width 8mm, length 60mm
8x80 = width 8mm, length 80mm
Type:
Recommended frequency range:
R = Radial probe
10-100 = from 10kHz to 100kHz
D = Encircling coil probe
EC12x60IRT10-100-S
Material of enclosure:
I = Stainless steel
P = Plastic material
Manual
Recommended frequency range:
10-100 = from 10 KHz to 100 KHz
Eddy current probe:
T = T-type
F = F-type
Recommended frequency range:
10-100 = from 10 kHz to 100 kHz
Eddy current probe:
Application:
T = T-type
= Round specimen
F = F-type
C = Coil (flat specimen)
Connection:
S = Plug connection
Type:
T = T-type (eddy current probe)
F = F-type (eddy current probe)
N = Normal differential coil
M = Multiple differential coil
Technical data
Connection:
S = Plug connection
Application:
= Round specimen
C = Coil (flat specimen)
Connection:
S = Plug connection
93