Fault Messages, Causes And Remedies - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
8

Fault messages, causes and remedies

Pos: 65 /Sc hweis snaht/ Geräte/ SN D40/9 Fehle rmel dungen/Feh lermel dunge n @ 0\mod _114 361 831 7062 _50 1.docx @ 199 3 @ 22 @ 1
Text of error message
Error while initialization of WIN sockets.
Unknown error.
Invalid data received.
System configuration was not
converted.
File error.
Internal error.
Program initialization failed.
Frequency table not loaded.
System configuration was not stored.
System configuration was not loaded.
Unable to copy program.
Unable to store program.
No active program.
Invalid program number.
Program parameter xxx invalid.
xxx = no. of parameter
(see rank in program file).
System parameter xxx invalid.
xxx = no. of parameter
(see rank in system file).
Parameter xxx in system settings
invalid. Please modify and restart
system.
xxx = designation of parameter, e.g.
"Language".
Unable to save job.
Invalid groups.
PM: receive buffer overflow.
PM: character not in hex format.
PM: message error - no STX.
PM: message – checksum wrong
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Error No.
Possible cause
via Field bus
-
Windows system error
-
Unspecific error.
20
Processor module is sending
invalid data. Bus connection or
hardware might be defective.
-
Invalid values for system
settings or memory error.
-
File cannot be read or has a
wrong format.
-
Unspecific error.
-
Error in the program file.
-
Error in the frequency file.
-
Error in Flash.
-
Error in the system file.
-
File already existing, insufficient
memory space
or error in Flash.
-
File already existing, insufficient
memory space
or error in Flash.
-
No valid program selected.
-
No valid program selected.
20
Special parameter is invalid.
-
Special parameter is invalid.
-
Special parameter is invalid.
-
File already existing, insufficient
memory space
or error in Flash.
20
Data quantity of groups (auto
correlation) does not match.
95
Too much data to proc. module.
Error at data transmission.
Error at data transmission.
Error at data transmission.
Manual
Fault messages, causes and remedies
Remedy
Re-install Windows CE
Re-start
Check RS232 connection between
processor module and communication
module – change hardware.
Check / re-enter parameters, change
hardware if required.
Create the program newly.
Re-start.
Re-teach.
Re-install.
Change KM hardware.
Re-enter system parameters or change
KM hardware.
Delete unused files,
check name.
Delete unused files,
check name.
Select a valid program.
Re-enter parameter.
Re-enter parameter.
Re-enter parameter.
Delete unused files, check name.
Delete program, re-teach.
Check RS232 connection / Hardware
error.
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents