Combination Sensor Ns12-Ec8X80Nt10-100-S; Combination Sensor Ns12Nh-Ec8X80Nt10-100-S - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
9.14

Combination sensor NS12-EC8x80NT10-100-S

Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
Pos: 88 /Sc hweis snaht/ Senso ren/N S1 2/NS12NH-EC 8x80NT 10-10 0-S Te chni sche Daten @ 1\mod_1 237 297 7444 21_ 501.d ocx @ 8 273 @ 2 @ 1
9.15

Combination sensor NS12NH-EC8x80NT10-100-S

Special feature:
Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
Pos: 89 /Sc hweis snaht/ Senso ren/N S1 2/NS12 Tec hnis che Zeic hnun g @ 0\mod_ 112 625 5328 000 _50 1.docx @ 584 @ 3 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material (ferrous / non-ferrous tubes)
12 - 250 mm
Up to 4 mm / depending on material
Magnetical leakage flux / eddy current
4 mm
10 - 40 °C (50 – 104°F) (operation)
IP53
11 kg (24.3 lbs)
Aluminum, nickel plated
KNS9S (leak flux)
CECM18S-G (eddy current)
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
extra-large width of measuring patch for tubes with rough surface
or heterogeneous weld seam.
Round material (ferrous / non-ferrous tubes)
12 - 250 mm
Up to 4 mm / depending on material
Eddy current, with pre-magnetization
20 mm
10 - 40 °C (50 – 104°F) (operation)
IP53
11 kg (24.3 lbs)
Aluminum, nickel plated
KNS9S (electro magnet)
CECM18S-G (eddy current)
0.2 ... 0.25 mm in new condition
0.1 ... 0.35 mm is permissible range
0.6 ... 0.65 mm in new condition
0.3 ... 0.75 mm is permissible range
Manual
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
Technical data