Sensor Ns24-Ec18X185Nt10-100-S - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
9.16

Sensor NS24-EC18x185NT10-100-S

Technical data
Application:
Diameter of tubes:
Wall thickness:
Measuring principle:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Air gap between pole boots
and tube surface
Air gap between sensor
element and tube surface
Number of rubber mounts
Pos: 91 /Sc hweis snaht/ Senso ren/N S2 4/NS24-EC18x 185N T10-1 00-S Te chn ische Zei chn ung @ 0\mo d_11 869 921 4123 4_5 01.do cx @ 45 40 @ 3 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material (ferrous tubes)
25 - 500mm (0.98 – 19.7in)
Up to 12.5mm / depending on material
Magnetical leakage flux / Eddy current
20mm
10 - 40°C (50 - 104°F) during operation
IP54
63 kg (139 lbs)
Aluminum, nickel plated
KNS9S and CECM18S-G
0.5 ... 0.55mm in new condition
0.3 ... 0.7mm is permissible range
0.5 ... 0.55mm in new condition
0.3 ... 0.7mm is permissible range
8
Manual
The air gaps must be within the permissible
range.
If the value gets – due to wearing - outside the
permissible range, the sensor needs to be
repaired (see also chapter 10 "Maintenance").
Technical data