Roland R4000 Manual page 15

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
2.3.5
Rotary speed of the tube
The rate of tube turns is mostly determined by the cycle time. See previous chapter „Cycle time
and duration of weld seam detection".
However, it may happen that a very short cycle time requires a very high tube rotation speed N.
This can lead to system-related limitations. To check use the formula below:
750
A
however > 5 rpm and < 300 rpm
There are no restrictions if the rate of tube turns N is within the limits.
2.3.6
Speed
At friction roller drive the speed of the surface / of the periphery is specified.
Whether system related limitations are observed can be checked using the following formula:
There are no restrictions if the velocity V is within the limits.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
K
<
N
<
D
A
D
Important:
During the detecting procedure the rotation rate of the tube must be
constant.
V = Speed [mm/sec.]
K
A = Scanning values per cm
10
<
V
<
A
K = 50.000
Important:
During the detecting procedure the speed must be constant.
Manual
N = Rate of tube turns [rpm]
D = Tube Diameter [mm]
A = Scanning values per cm
(item in program parameter 5... 120)
K = 1.000.000
(item in program parameter 5... 120)
System description
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents