Technical data
9.23

Eddy current probe EC4x40IRF50-400-S

Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Arrangement:
Width of track:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Sensor Connection Box:
2
1
Abb. 61: EC4x40IRF50-400-S
Pos: 100 /Schweis snah t/Sen sore n/EC (Wirbe lst romso nden)/EC5x3 0IF1 0-100- S @ 0\mod _11 2955 847 3328 _50 1.docx @ 844 @ 2 @ 1
116
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material
Flat material
unlimited
Depending on material
Eddy current (high resolution)
radial
1 mm
1.5 mm
10 - 40° C (50 – 104°F) (operation)
IP65
0.15 kg (0.33 lbs.)
Stainless steel
CECM18S-G
SCB-EC-S
2
3
4
5
Manual
Description
20
Ø
1:
2:
3:
4
Ø
4:
5:
All dimensions in mm.
SW18
SW14
20
Ø
B0059001 / Rev. 2.3
View – active area
Direction of material
flow
Marking
Sleeve Ø 5 x 0.5
made of INOX
Cable plug
Order no.: 2277704