Roland R4000 Manual page 152

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

Technical records
Standard wiring of interface
Operational condition: Setup – Edit (X/Y)
Condition!
1.
The unit must be in "Setup - Edit" condition.
2.
System parameter "Test job control mode: KM" (by SND40 key)
3.
X/Y operation (started / terminated by key operation).
4.
The PLC must already have the tube prepared for rotation. The PLC must then accordingly output the signal "motor"
to rotate the tube.
Parallel Data Outputs
OUT0 / Start Test job active
OUT2 / Ready for measuring
OUT3 / Setup active
OUT5 / General fault
t1:
< 100 ms
t2:
The user will terminate the X/Y operation with the <Stop> key.
t3:
< System parameter "time"
t4:
≥ 0 ms
t5:
> 30 ms
The total duration of the X/Y operation will be determined via key operation by the user.
1)
Not mentioned inputs / outputs of the interface are not required for parameter programming.
152
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Key / Start
Key / Stop
1)
OUT7 / Motor
Manual
t1
t2
t3
B0059001 / Rev. 2.3