Connecting Of Sensor; Connecting Of Probe - Roland R4000 Manual

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

Electrical installation
4.4

Connecting of sensor

The sensor should be connected only by an electrician.
Fig. 19: Grounding
The sensor cable KNS9S-G and CECM18S-G are supplied by ROLAND ELECTRONIC. A different
naming of the cable is possible - see „Technical data". At the sensor side those cables are
equipped with a round plug. The other side is prepared with splice ferrules.
The wires need to be connected to the assigned cable terminals. For doing so, the terminal strips
can be detached.
Pos: 30 /Sc hweis snaht/ Senso ren/E lektrisc he In stalla tion/ Sonde nans chlu ss @ 0\mod_1 143 1195 923 75_ 501.do cx @ 19 47 @ 23 @ 1
4.5

Connecting of probe

The eddy current probe has a connecting cable of 1 meter length. The cable is connected to the
Sensor Interface Box SCB-EC-S with the M12 round plug.
With the sensor cable CECM18S-G the Sensor Interface Box is connected to the SND40. The
sensor cable is supplied by ROLAND ELECTRONIC. Different naming of the cable is possible -
see „Technical data".
At the side of the interface box the cable is equipped with a round plug. At the side of the SND40
the cable leads are prepared with splice ferrules.
The wires need to be connected to the assigned connecting terminals. For doing so, the terminal
strips can be detached.
40
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Special note:
When connecting the sensors, take care that the cable shields get connected with
the provided terminals or flat contacts. If grounding connections are present at the
sensors, they must be connected to grounding in every case.
3
1
Manual
2
4
B0059001 / Rev. 2.3
Description
1:
Sensor
2:
Control unit SND40
3:
Grounding terminal
4:
Central machine grounding