Roland R4000 Manual page 47

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

B0059001 / Rev. 2.3
As connection plug standardized shielded SUB D 9 Profibus connectors are suitable.
The use of connection plugs with integrated (switchable) terminating resistors is recommended.
If the SND40 is placed at the bus end / begin, the terminating resistor must be switched on.
Fig. 26: Profibus module cable
Fig. 27: SND40 Profibus module
The bus address can also be set in the system configuration of the SND40. To do this, the switches
on the module must be set to 00.
Pos: 36 /Sc hweis snaht/ Geräte/ SN D40/5 E lektrisc he In stal lation/P rofiNe t IO - An schl uss @ 1\mod_ 120 0483 457 781_ 501. docx @ 5 353 @ 3 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Manual
View of module with connected cable
Allocation of the Profibus plug
Color of wire
red
green
Shield
Factory setting on Profibus module
1: Bus termination
downward
upward
2: Slave address (00)
Both turn switches in pos. 0
(00) means, the slave address is
determined by the system configuration
Electrical installation
D- SUB
Name
Pin 3
P (B-Line)
Pin 8
N (A-Line)
Enclosure
-
=
ON
=
OFF
47