B0059001 / Rev. 2.3
9.24
Eddy current probe EC5x30IF10-100-S
Technical data
Application:
Diameter of tube:
Wall thickness:
Measuring principle:
Arrangement:
Width of track:
Width of measuring patch:
Ambient temperature:
Class of protection:
Weight:
Material of enclosure:
Sensor cable:
Sensor Connection Box:
2
3
Fig. 62: EC5x30IF10-100-S
Pos: 101 /Schweis snah t/Gerä te/SN D40/2 Techn isc he Date n/An sch luss schema (al lgemei n) @ 1\mod_ 1224 833 650 000_ 501. docx @ 7 669 @ 3 @ 1
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Round material
flat material
unlimited
Depending on material
Eddy current (high resolution)
axial
1.5 mm
2 mm
10 - 40 °C (50 – 104°F) (operation)
IP65
0.15 kg (0.33 lbs)
Stainless steel
CECM18S-G
SCB-EC-S
1
2
5Ø
Ø5 x 0.5
4
5
Ø20
Manual
Description
1:
2:
3:
4:
5:
All dimensions are in mm.
Technical data
View – active area
Direction of material flow
Marking
Sleeve Ø 5 x 0.5,
made of Stainless steel
Cable plug
order no.: 2277704
117