B0059001 / Rev. 2.3
11.2.4.2 Exchanging the leakage flux module
Fig. 87: Exchanging the leakage flux module
Loosen all cable plugs and the 4 fixing screws.
Every screw connection consists of an M3 screw, a toothed washer and a flat washer.
Do not lose any parts, danger of short-circuit.
Carefully pull the module at the upper and lower side, in order to loosen it from its socket.
Insert the modified leakage flux module with the same orientation into the socket.
If the module has been correctly inserted, the fixing holes and the holes of the support bolts
match.
Re-fasten the module with the screws and put-on the cable plugs again.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
Manual
Technical records
Change of components
Leakage flux