Roland R4000 Manual page 30

Weld seam detection system
Hide thumbs Also See for R4000:
Table of Contents

Advertisement

Mounting
3.1.1
Rubber mount assembly of the NS9
Four rubber mounts are included in the scope of supply.
In each case two buffers have to be installed diagonally
shifted on the narrow sensor sides.
Fig. 9: NS9 Rubber mount
Pos: 20 /Sc hweis snaht/ Senso ren/N S1 2/NS12 Zeich nung Mo ntage Gummi puffer @ 0\mod_1 127 2127 044 21_ 501.do cx @ 5 85 @ 3 @ 1
3.1.2
Rubber mount assembly of the NS12 / NS24
Eight rubber mounts are contained in the scope of
supply. In each case four buffers are installed on the
narrow sensor sides.
Note For the NS24 sensor use only the
Fig. 10: NS12 rubber mount assembly
Pos: 21 /Sc hweis snaht/ Senso ren/Mon tage/EC-So nden/Monta ge der W irbe lst romso nden @ 0\mod_1 143 1091 538 43_ 501.do cx @ 19 19 @ 2 @ 1
30
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Weld Seam Detection System R4000 SND40
for Tubes, Cans and Drums
rubber mounts intended for this
sensor!
Refer to chapter 9,
section "rubber mounts"
Manual
B0059001 / Rev. 2.3
M8
M8
M8
M8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Snd40

Table of Contents