Replacing A Cpu Or Heat Sink - Fujitsu PRIMERGY RX4770 M5 Upgrade And Maintenance Manual

Table of Contents

Advertisement

11.4

Replacing a CPU or heat sink

Field Replaceable Unit
(FRU)
Tools:
Phillips PH2 / (+) No. 2 screw driver
CAUTION
CPUs are extremely sensitive to electrostatic discharge and therefore
must always be handled with care.
After a CPU has been removed from its protective sleeve or from its
socket, place it upside down on a nonconducting, antistatic surface.
Never push a CPU over a surface.
In case of dealing with CPUs in a liquid cooling configuration, see
chapter
"Liquid cooling (LC)" on page
Preliminary steps
For CPU 1 and 2 (bottom system board)
"Suspending BitLocker functionality" on page
"Shutting down the server" on page
"Disconnecting the power cord" on page
"Removing the server from the rack" on page
"Getting access to the component" on page
▶ Remove the air duct from the top system board, see
air duct" on page
"Removing the riser module 3/4 and 6/7" on page
"Removing the fan cage" on page
"Removing the top system board holder" on page
▶ Remove the air duct from the bottom system board, see
CPU air duct" on page
RX4770 M5
72.
69.
72.
Upgrade and Maintenance Manual
Hardware: 15 minutes
Software: 5 minutes
371.
85.
45.
46.
49.
47.
"Removing the CPU
61.
74.
Processor (CPU)
"Removing the