Processor (CPU)
Concluding steps
"Installing the air duct" on page
"Reassembling" on page
"Connecting the power cord" on page
"Switching on the server" on page
▶ If applicable,
"Installing the front cover with lock" on page
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
● Restart your server.
● As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
● If a password is assigned, enter the password and press [Enter].
● Select the Exit menu.
● Select Commit settings and Exit.
● Verify that the Global Error indicator stops flashing.
11.4

Replacing a CPU or heat sink

Field Replaceable Unit
(FRU)
Tools:
– Phillips PH2 / (+) No. 2 screw driver (for cover 2)
– Torx 30 screw driver (for CPU heat sink)