Table 4.1 Error Display of Operator and Trace Back Table
Alarm Code
Number
Letter
Motor over-current
10
SC
If it cannot be cancelled even if it's not over-current, it's overheat.
11
oC
Motor over-current
12
oH
Operation error due to motor overheat or noise
20
tol
Instantaneous over load of torque command
21
tOL
Continuous overload of torque command
22
Fol
Instantaneous overload of motor current
23
FOL
Continuous overload of motor current
30
EOP
Encoder open
Pulse error (difference between the pulse command and motor movement)
33
PoF
overflow
35
EuV
Low voltage of inner capacitor of absolute encoder
36
EoP
Error in initializing encoder
37
Eos
Over-speed during electricity failure of absolute encoder
40
oS
Over-speed detection
41
ESt
Emergency stop
50
oV
Over voltage
62
uOF
Offset trouble in current sensor U phase
63
UoF
Offset trouble in current sensor V phase
70
tuV
Momentary electricity failure
71
uV
Control power cut-off
80
CHE
Parameter damage
81
Pro
Parameter range check error
82
EtP
Motor setting or encoder setting error
Alarm Content
-