Parameter
SEt-43
6-40
• Torque Limit Detection Output Signal
In order to use
TG-ON+
detection signal, SEt-43 LED No.4 must be set to "1".
LED
Setting
0
(This signal is ON when motor speed is higher than zero-speed level.)
No. 4
1
TG-ON+ Signal becomes torque(current)limit detection signal.
Fig 6.32 External Torque Limit Command and Torque Limit
Detection Output Signal
(CN1 pin 43) output signal as torque limit
Description
TG-ON+ Signal becomes motor rotation detection signal.