Motor
7-10
Allowable Load Inertia
- The table below displays the maximum inertia ratio (load inertia/
motor inertia) of the load, which can be attached in each motor. It
is based on the regenerative energy absorbable in the capacitor
(during deceleration) at the horizontal load.
- When operating the load larger than the allowable load inertia,
connect a regeneration resistor or auxiliary capacitor.
Table 7.2 Allowable Load Inertia Ratio(When regeneration
resistor is not connected and when operated at a
rated speed)
A3B
10B
A5B
30W
1kW
50W
30
3.5
30
-
-
-
-
-
-
30
-
30
Above inertia is the maximum value thus use with suffi-
cient allowance. When connecting a load larger than the
allowable load inertia, connect a regeneration resistor,
regeneration unit or auxiliary capacitor. When connecting
a load larger than the allowable load inertia and using
repeatedly, electrolytic capacitor may be damaged or the
lifespan of the drive may be reduced.
220V
01B
02B
04B
100W
200W
400W
30
23
12
26
10
5
27
12
6
30
30
28
06B
08B
600W
800W
7
6
-
-
-
-
12
5