Speed Command
Torque Command
SEt-44 LED No.1
SEt-44 LED No.2
6-18
Selection of Stop Method
Offset Adjustment
When 0V is specified as analog input voltage for speed/torque
command, the motor may rotate at a very slow speed and fail to stop.
This happens when analog input voltage form the host controller or
external circuit has a slight voltage offset (in mV unit). If this offset is
adjusted to 0V, the motor will stop.
Manual Adjustment
For detailed adjustment procedures, refer to Using the Operator.
Using the DB(Dynamic Brake)
-
Set motor stop method after the Servo OFF
Setting
0
Stop using dynamic brake. (Factory setting value)
1
Stop after the free run.
-
Set the operation after motor stop using the dynamic brake.
Setting
0
Dynamic brake is off after the motor stopping.
Dynamic brake is on even after the motor stopping. (Factory setting
1
value)
Fig 6.13 Selection of Stop Method
USr-05
USr-06
Description
Description
Auto Adjustment
USr-03
USr-04