OE Max Controls CSDJ Plus User Manual page 156

Hide thumbs Also See for CSDJ Plus:
Table of Contents

Advertisement

Parameter
SEt-29
SEt-30
SEt-31
SEt-76
7-4
Brake Control
Brake control is used when applying the servo drive to control of the
vertical axis.
In motor stop status, use brake attachment motor so the load is not
moved by gravity
Table 7.1 Brake Control Setting Parameter
Description
Time it takes actually to turn the servo off inside from the
point of time where servo OFF signal has been ON when the
motor is stopped.
Speed of the motor when the braking command is on when
the Servo OFF signal has been input during the motor
operation.
Waiting time from the input of Servo OFF signal when the
motor is operating, until the output of brake command.
Time it takes for brake release signal is output from internal
Servo ON signal.
• Servo Off and Brake Control Signal Timing When the
Motor is Locked
In case the load moves a little due to the gravity when the servo is
turned OFF , set the delay time appropriately from the point where
the servo off signal has been input in SEt-29 up to the actual point
when the internal servo is OFF .
If Servo OFF signal is on when the motor is stopped,
immediately turn ON the BK signal.
Maintain servo on status internally according to the time
set in SEt-29 from the point when Servo OFF signal has
been on. Then turn the Servo OFF when the set time is
exceeded.
.
Brake attached to the motor cannot be used for stopping
rotation.Just use it to lock the stopped motor in that sta-
tus.
Setting
Factory
Unit
Range
Setting
10msec
0 ~ 1000
0
RPM
0 ~ 5000
100
10msec
0 ~ 1000
50
10msec
0 ~ 1000
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Csdj-01bCsdj-02bCsdj-04bCsdj-06bCsdj-10b

Table of Contents