Rotation Detection Output Signal
Parameter
Name
SEt-43
Selection of TG-ON
Output Signal Function
LED No.4
SEt-16
TG-ON Speed Level
Operate in all control modes.
When SEt-43 LED No.4 = 1, TG-ON signal operates as other function
(Uses TG-ON as a torque limit output signal.)
This signal can be used as reference signal of host controller.
Fig 6.29 Rotation Detection Output Signal
Setting
Setting Value
Range
0
0,1
(Factory setting)
20
0~1000
(Factory setting)
Unit
Description
Uses TG-ON as a Rotation
-
detection output signal.
RPM