Check Items prior to Startup
Servo Motor
Check the items listed below prior to the startup. When the system is
unused for long period of time, check it according to the maintenance
and check up list prior to the startup.
Check if the connection, grounding, and conditions of the
external equipment are done appropriately when con-
necting the drive with the serve motor.
Check if there is any loose parts
Check if the Oil Seal part has been damaged (for those
with the oil seal attached). Check the condition of the oil
and take appropriate action immediately in case of prob-
lem.
Servo Drive
Check if the system is set properly according to the speci-
fication of applied servo motor.
Check if the connection and wiring LEAD are properly con-
nected to the terminal and if they are plugged into the
connector properly.
Check if the sequence is set up so the power can be turned
off by the Servo Alarm.
Check if the voltage supplied to the servo drive is actually
supplied with an appropriate power. (Single phase
220VAC, +10, -15%, 50/60Hz)
Check if the polarity of DC voltage supplied to the servo
drive is correct. (24VDC
Check if 0V is applied for speed command.
Check if the motor type, capacity and encoder type are set
exactly. (They can be checked in SEt-51 ~ SEt-53).
For modification, turn the power off and on again, then
initialize the parameter in USr-09.
Take appropriate action immediately if there are any problems in the
above.
±