Figure 3-45 4-Amp Power Supply Unit - Inter-Tel AXXESS Manual

Hide thumbs Also See for AXXESS:
Table of Contents

Advertisement

Installation
®
®
INTER-TEL
AXXESS
Figure 3-45.
4-Amp Power Supply Unit
ON/OFF SWITCH
Grounding Requirements
9.8
AC power source. (See
points include the building's frame, a ground rod (driven a minimum of 8 ft), and a copper (not
PVC) cold water pipe.
9.9
grounded AC power source. (See
net and Krone field should also be hardwire earthed to the building earth.
9.10 In addition, all optional Single-Line Adapters, trunk gas discharge tubes, and UPS/SPS
battery compartments that are used must be properly grounded to the chassis AC outlet. Inter-
Tel's CommSource division or Inter-Tel Europe sells a surge/spike protector that has a built-in
ground lug just for this purpose.
9.11 The grounding wire should be 10AWG (10 gauge thickness or larger -- smaller number
gauge = larger thickness) or larger and should not exceed 25 feet (7.5 meters) to help provide
RFI/EMI protection, or it should not exceed 10 feet (3 meters) to help provide both RFI/EMI
and lightning protection.
Page 3-88
MANUAL VERSION 11.0 – May 2008
-5V
+5V
+24V
-5V
+5V
+/-5V GND
+24V
+24V GND
With a U.S. system, the equipment chassis must be plugged into a properly grounded
page 3-10
With a European system, the equipment chassis must be plugged into a properly
LED INDICATORS
VOLTAGE TEST POINTS
AC POWER PLUG
110/115V 4A
230/240V 2A
47-63 Hz
LIFT LEVER
TO REMOVE
for additional AC power requirements.) Some good ground
page 3-10
for additional AC power requirements.) The cabi-
4-Amp Power Supply Unit