Toshiba B-EP Series Interface Specification page 692

External equipment interface specification
Hide thumbs Also See for B-EP Series:
Table of Contents

Advertisement

NOTE 1: When a command error has been found in the sent command, 16-byte command code of the
erroneous command is displayed on the LCD. (However, [LF] and [NUL] are not displayed.)
[Example 1]
Command error
[Example 2]
Command error
[Example 3]
Command error
NOTE 2: When the command error is displayed, "? (3FH)" is displayed for codes other than 20H to 7FH
and A0H to DFH.
:
Blinking (red)
NOTE 3:
:
ON (red)
:
ON (green or orange)
:
Blinking (green)
:
Dimmed
****:
Remaining number of labels to be printed 0001 to 9999
####:
Remaining memory capacity of PC save area in the flash memory:
0 to 3,200 (in K bytes)
&&&&: Remaining memory capacity of writable character / basic files / forms / graphics storage area
in the flash memory
0 to 3,200 (in K bytes)
- -:
System error No.: 00 to 21
$:
Charging error No.: 1 to 5
11.13 LIST OF CHARGING ERROR NO. AND DETAILS
No.
Description
Battery ID error
1
Abnormal battery temperature
2
Abnormal current (during
3
trickle charging)
Trickle charging timeout
4
Abnormal current (during
5
normal charging)
[ESC] PC001; 0A00, 0300, 2, 2, A, 00, B [LF] [NUL]
LCD display
[ESC] T02A G30 [LF] [NUL]
LCD display
[ESC] XR; 0200, 0300, 0450, 1200, 1 [LF] [NUL]
LCD display
Cause
It is detected that no battery is loaded or that an
inappropriate battery is loaded.
8.7V or over for B-EP2DL
17.4 V or over for B-EP4DL
1.2A or over for B-EP2DL
2.0A or over for B-EP4DL
Transition to normal charging does not take place after trickle
charging for 90 minutes.
1.2A or over for B-EP2DL
2.0A or over for B-EP4DL
11-18
PC001;0A00,0300,
T20A30
XR;0200,0300,045
CHAPTER 11 OTHER FUNCTIONS
B-EP Series
(in units of 1 label/tag)