Toshiba B-EP Series Interface Specification page 430

External equipment interface specification
Hide thumbs Also See for B-EP Series:
Table of Contents

Advertisement

6.5.13 TWO-DIMENSIONAL CODE FORMAT COMMAND
Function
Sets the format to indicate the position on the label, at which the two-dimensional code
is to be printed and how it is to be printed.
Format
[ESC] XBaa; bbbb, cccc, d, e (, Jffgg) (, Zh), iii, j, k [LF] [NUL]
Term
aa:
bbbb: Print origin of X-coordinate of the two-dimensional code
cccc:
d:
e:
Jffgg:
Zh:
iii:
j:
k:
Two-dimensional code No.
00 to 99
(The same No. must not be used in one form for the bit map font field, the
outline font field, and the two-dimensional code field.)
Fixed at 4 digits (in units of 0.1 mm)
Print origin of Y-coordinate of the two-dimensional code
Fixed at 4 digits (in units of 0.1 mm)
Type of two-dimensional code
Z: Maxicode
Mode selection
2: Mode 2
3: Mode 3
4: Mode 4
6: Mode 6
Connection setting (Omissible. If omitted, no connection is made.)
ff:
Code number 01 to 08
gg: No. of divided codes 01 to 08
Attachment of Zipper block and Contrast block
(Omissible. If omitted, the Zipper block and Contrast block are not attached.)
h:
0: No attachment of Zipper block and Contrast block
1: Attachment of Zipper block and Contrast block
2: Attachment of Zipper block
3: Attachment of Contrast block
Data length
000 to 100
NOTES: 1. A two-digit value (00 to 99) is also available.
2. When "00" is designated, the length is equivalent to the data sent
by the Data Print Command (data which is delimited by [LF].)
Data code
1 (Fixed value): JIS8 code
Reserved area
0 (Fixed value)
CHAPTER 6 LABEL MODE (INTERFACE COMMANDS)
(MAXICODE)
6-49
B-EP Series
[ESC] XB

Hide quick links:

Advertisement

Table of Contents
loading