Toshiba B-EP Series Interface Specification page 308

External equipment interface specification
Hide thumbs Also See for B-EP Series:
Table of Contents

Advertisement

Explanation
(1)
Two-dimensional code number
When drawing by the Data Command ([ESC] RB), the format designated by the two-
dimensional code number is selected.
(2)
Print origin of coordinates
Origin of
coordinates
(0, 0)
Effective
print
length
X
0
print width
Y
[Printing direction: Bottom first]
The print origin of coordinates must be set so that the two-dimensional code drawing
result will be within the effective print area set by the Label Size Set Command ([ESC] D).
(3)
Type of two-dimensional code
Z:
MaxiCode
(4)
Data string to be printed
Drawing data can be programmed by designating the number of digits after the symbol
"=." The maximum number of digits to be printed is 93.
(5)
Connection setting
For MaxiCode, data can be divided into several codes. The data can be divided into a
max. of 8 codes.
Backing paper
Label
Print origin of
coordinates
Effective
Paper feed direction
CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
Effective
print
length
Y
0
X
[Printing direction: Top first]
5-138
B-EP Series
Backing paper
Label
Print origin of
coordinates
Origin of
Effective
coordinates
print width
Paper feed direction
(0, 0)