Toshiba B-EP Series Interface Specification page 406

External equipment interface specification
Hide thumbs Also See for B-EP Series:
Table of Contents

Advertisement

6.5.3
OUTLINE FONT FIELD COMMAND
Function
Sets the format to indicate the position on the label, at which the outline font is to be
printed and how it is to be printed.
Format
[ESC] PVaa; bbbb, cccc, dddd, eeee, f, (,ghh), ii, j, kk, l, m, (,Pn) (,Qoooo,Rppp) [LF]
[NUL]
Term
aa:
bbbb: Print origin of X-coordinate of character string
cccc:
dddd: Character width
eeee
f:
ghh:
ii:
j:
kk:
l:
m:
Character string No.
00 to 99
(The same No. must not be used in one form for the bit map font field, the
outline font field, and the barcode/two-dimensional code field.)
Fixed at 4 digits (in 0.1 mm units)
Print origin of Y-coordinate of character string
Fixed at 4 digits (in 0.1 mm units)
0020 to 0300 (in units of 0.1 mm)
Character height
0020 to 0300 (in units of 0.1 mm)
Type of font
A: TEC Font 1 (Helvetica [Bold])
B: TEC Font 1 (Helvetica [Bold], Proportional)
F: Price Font 2
K: Reserved
C, D, E: Reserved (If specified, it is processed as "B.")
Character-to-character space width (Omissible. If omitted, the character-to-
character space width depends on the designated font.)
g:
+, -
hh: 00 to 99 (dot)
Rotational angles of a character and character string
00:
0° (chara.)
01:
90° (chara.)
02:
180° (chara.)
03:
270° (chara.)
Selects black character or reverse character
B (Fixed value): Black character
Data length
00 to 99
NOTE:
When "00" is designated, the length is equivalent to the
data sent by the Data Print Command.
Data code
1: JIS8 code
2: Packed BCD code (only for IrDA: TEC Protocol)
Fixed data No.
0 (Fixed value)
CHAPTER 6 LABEL MODE (INTERFACE COMMANDS)
[ESC] PV
0° (chara.-string)
90° (chara.-string)
180° (chara.-string)
270° (chara.-string)
JIS8 code: Data which is delimited by [LF]
Packed BCD code: Data which is delimited by "F"
6-25