Toshiba B-EP Series Interface Specification page 206

External equipment interface specification
Hide thumbs Also See for B-EP Series:
Table of Contents

Advertisement

Mm:
Type of check digits to be attached
(Omissible. If omitted, no check digit is drawn.)
m:
Type of check digit
0: Modulus 10 (draws data and check digit.)
1: Modulus 43 (draws data and check digit.)
2: DBP Modulus 10 (Draws check digit only.)
* Reserved in the case of the compatible mode for the B-SP series
noooooooooo: Increment and decrement
(Omissible. If omitted, increment/decrement is not performed.)
n:
Designates whether to increment or decrement.
+:
Increment
-:
Decrement
oooooooooo:
Skip value
0000000000 to 9999999999
Zpp:
Zero suppress (Omissible. If omitted, zero suppression is not performed.)
pp:
No. of digits after zero suppression
00 to 20
* Reserved in the case of the compatible mode for the B-SP series
Pq:
Alignment (Omissible. If omitted, the alignment is set to the left.)
q: Designates the character position
1: Left
2: Center
3: Right
4aaaa:
Justification
aaaa:
0050 to 1040 (in 0.1 mm units)
5aaaabbbcc:
aaaa:
0050 to 1040 (in 0.1 mm units)
bbb: Line feed spacing
010 to 500 (in 0.1 mm units)
cc: No. of lines
01 to 99
rrr ------ rrr: Data string to be printed (Omissible)
Max. 255 digits
ss
, ss
, ss
------ , ss
: Link field No. (Omissible)
1
2
3
20
CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
Character string in the X direction
Automatic line feed
Character string in the X direction
01 to 99 (1 to 99 can also be used.)
Up to 20 fields can be designated using commas.
5-36