Toshiba B-EP Series Interface Specification page 230

External equipment interface specification
Hide thumbs Also See for B-EP Series:
Table of Contents

Advertisement

When one field width < specified character string width
(Space between characters < 0, Specified character string digits = 8)
■ Print image when the parameter setting is omitted.
1 field width (125 dots)
A B C D
Specified character string width (200 dots)
Corrected space between characters = ((Specified character string digits – data length)
( x 0.5 + 1) x Space between characters = -15 dots
A = Specified character string width – (1 character width x Data length
+ (corrected space between characters x (Data length – 1))
= 200 dots – 95 dots = 105 dots
B = A/Data length = 105 dots/4 ≈ 26 dots (rounded down)
One character width = 1 character width + B = 35 dots + 26 dots = 61 dots
* The minimum. corrected space between characters is - 99 dots.
* The calculated one character width is doubled when doubled or more from the original one
character width.
■ Print image when the parameter setting is specified.
Space between characters (-15 dots)
A
Specified character string width (199 dots)
* When the number of print data is 8 digits or more, the condition of ineffectiveness (3) is satisfied.
In this case, the characters are printed in normal width.
A
One character width (35 dots)
Space between characters (-5 dots)
One character width (61 dots)
B
C
5-60
CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
D
B-EP Series

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents