When the manual mode is selected in the Format Command for a QR code
• Numeric mode, alphanumeric and symbol mode, Kanji mode
Mode selection
• Binary mode
Mode selection
• Mixed mode
Data
The QR code can handle all codes including alphanumerics, symbols and Kanji.
Since data compression rate varies according to codes, the code to be used is
designated when the mode is selected.
Mode
N
A
B
K
If mixed mode is selected, up to 200 modes can be selected in a QR code.
When the automatic mode is selected in the Format Command for a QR code.
Data to be printed
How to send the control code data
NUL (00H)
SOH (01H)
STX (02H)
GS (1DH)
RS (1EH)
US (1FH)
How to send the special codes
> (3EH)
CHAPTER 6 LABEL MODE (INTERFACE COMMANDS)
Data to be printed
No. of data strings
(4 digits)
"," (comma)
Data
Code
Numerals
Alphanumerics, symbols A to Z 0 to 9 space
Binary (8-bit)
Kanji
=
> @ (3EH, 40H)
=
> A (3EH, 41H)
=
> B (3EH, 42H)
=
> ]
(3EH, 5DH)
=
> ^
(3EH, 5EH)
=
> _ (3EH, 5FH)
=
> 0 (3EH, 30H)
6-60
Data to be printed
"," (comma)
Details
0 to 9
$ % * + - . / :
00H to FFH
Shift JIS