Toshiba B-EP Series Interface Specification page 354

External equipment interface specification
Hide thumbs Also See for B-EP Series:
Table of Contents

Advertisement

Print origin of
coordinates
Graphic
height
22 dots
4
8
[Nibble mode]
(1)
The graphic data is separated into four dot units and sent in above-mentioned order (1
132). (Upper digit: "3")
(2)
The graphic data is 30H to 3FH.
(3)
The minimum unit in the X direction is 8 dots. Dots with no data are transmitted as data
0.
(4)
The graphic data count must be as follows:
Graphic data count = {(No. of graphic width dots + 7)/8} × No. of graphic height dots × 2
* The value in the brackets is rounded down to the nearest whole number.
[Hex. mode]
(1)
The graphic data is separated into eight dot units and sent in above-mentioned order (1
66).
(2)
The graphic data is 00H to FFH.
(3)
The minimum unit in the X direction is 8 dots. Dots with no data are transmitted as data
0.
(4)
The graphic data count must be as follows:
Graphic data count = {(No. of graphic width dots + 7)/8} × No. of graphic height dots
* The value in the brackets is rounded down to the nearest whole number.
Graphic width 19 dots
4
4
4
4
8
CHAPTER 5 TPCL-LE MODE (INTERFACE COMMANDS)
1
30H
7
30H
127 33H 128 3FH 129 30H 130 30H 131 30H 132 30H
4
8
5-184
Nibble mode
2
3
4
5
30H
33H
30H
8
30H
Hex. mode
1
2
3
00H
30H
00H
4
5
00H
38H
63
00H
64
65
66
3FH
00H
00H
B-EP Series
6
30H
30H
126 30H

Hide quick links: