(3) When interrupting communication with the 2nd label command separator, and then
transmitting subsequent data,
1st transmission:
{AY;+00,1,3|}
{D0230,0480,0200|}
{C|}
{LC;0010,0010,0470,0060,1,2|}
{XB00;0200,0050,0,3,02,0,0050,+0000000000,020,1,00|}
{RB00;0000001|}
{XS;I,0001,0000C2011|}
{AY;+00,1,3|}
{D0230,0480,0200|}
{C|}
{LC;0010,0010,0470,0060,1,2|}
{XB00;0200,0050,0,3,02,0,0050,+0000000000,020,1,00|}
Interrupts communication with the
 
command separator.
2nd transmission:
{RB00;0000002|}
{XS;I,0001,0000C2011|}
Print result:
The 1st label data is printed after the 1st transmission, and the 2nd label data is
printed after the 2nd transmission.