(2) When interrupting communication while the 2nd label command is running, and then
transmitting subsequent data,
1st transmission:
{AY;+00,1,3|}
{D0130,0480,0100|}
{C|}
{LC;0010,0010,0470,0060,1,2|}
{PC00;0030,0050,2,1,a,00,B,+0000000000|}
{RC00;2inch 0001|}
{XS;I,0001,0000C2011|}
{AY;+00,1,3|}
{D0130,0480,0100|}
{C|}
{LC;0010,0010,0470,0060,1,2|}
{PC00;0030,0050,
Interrupts communication while the
command is running.
2nd transmission:
2,1,a,00,B,+0000000000|}
{RC00;2inch 0002|}
{XS;I,0001,0000C2011|}
Print result:
 
Transmits subsequent
data.
as shown below is printed after the 1st transmission, and
is printed after the 2nd transmission.
 
2 inch 0001
 
2 inch 0002
CHAPTER 4 TRANSMISSION SEQUENCE
1st label data
2nd label data
4-7
B-EP Series
as shown below