Command packet in the LABEL mode (Host → Printer)
Length is designated in 1 byte:
STX
Printer ID
Length
02H
xxH
xxH
xxH
Length is designated in 2 bytes:
STX
Printer ID
02H
xxH
xxH
00H
• Printer ID ......... 2-byte hex data (in order from High to Low)
• Length ............. Hex data indicating the number of bytes of command data
• When the length is designated in 1 byte: 1 byte
• When the length is designated in 2 bytes: 3 bytes
• CRC ................ 2-byte hex data (in order from Low to High)
* Between the start and the termination of storing the form, a packet including several commands
can be sent. However, the command data should not be included in two packets. For other
commands, one packet should include only one command.
* For all commands except the Graphic Data Store Command, data included in several packets
should not be sent. The Data Print Command can also send data included in several packets
if it is sent using the format on the next page.
Command
Range of the length
Length
xxH
xxH
Range of CRC calculation
01H to FFH
The first 1 byte is fixed at 00H.
Designate the length using the remaining 2 bytes.
(in order from Low to High): 0001 H to 0FFFH
3-8
Command
Range of the length
CHAPTER 3 INTERFACE
B-EP Series
CRC
xxH
xxH
CRC
xxH xxH