Toshiba B-EP Series Interface Specification page 432

External equipment interface specification
Hide thumbs Also See for B-EP Series:
Table of Contents

Advertisement

(4) Rotational angles of a barcode
Origin
NOTE:
If a barcode is rotated at 90° or 270°, the print density may become lower
in relation to the bar height. A barcode with a height of 14 mm or less
should be used. When a barcode with a height of over 14 mm is used,
the print quality is not guaranteed.
Rotational angle of a two-dimensional code
Point of origin
(5) Barcode height
(6) Numerals under bars
Numerals are provided under bars depending on the parameter for numerals
under bars. Standard fonts are used.
(7) Since the start/stop codes are not automatically attached when using NW7, they
should be included in the data to be sent as required. Although no start/stop
codes are attached to data, a barcode is drawn.
When using CODE39, the first and last characters of the data are checked.
Unless the characters are not "*," "*" is automatically attached. When the host
sends data while attaching "*" as the start/stop codes, a barcode is drawn.
(8) When Interleaved 2 of 5 is selected and the number of data length digits is odd, 0
is automatically added to the beginning of the data, to change the number of data
length digits to even.
CHAPTER 6 LABEL MODE (INTERFACE COMMANDS)
Origin
90°
180°
90°
180°
Height of
barcode
4 9 4 0
0 4 5 8
6-51
Origin
Origin
270°
270°
Height of
guard bar
B-EP Series

Hide quick links:

Advertisement

Table of Contents
loading