HONDAMATIC
24-36
4.
Mode Select Switch
Line Inspection
Turn the ignition switch OFF.
Disconnect
the ECM 21P (Black) con nector
Check for continuity
ECM
21P (Black) connector
t
erminals of
the
wire harness side with
the mode
select switch in each
mode position.
~r
Orange
Bluel
Black!
Green
Position
blade:
green
01
02
(>
ESP
Is there
normal
continuity?
NO
-
Replace the mode select switch
YES
- GO
TO STEP
4.
5. Mode Select Switch
line Inspection !Handlebar
switch side)
Check
for continuity at the switch side 4P (Black)
connector
in
the same manner as the STEP 4
(page 24-36).
Is there
continuity?
NO
- Faulty
mode select switch
YES
-
Open
o
r
short circuit in wire between
the
ECM
and
the
mode select switch
6.
M et
er Line
Inspection
Turn the ignition switch OFF.
Disconnect the
ECM
21
P
(Gray)
connector, com-
bination
meter
4P (Yellow) con
nect
o
r
and
the
combina tion
met er
14P
(G ray) connector.
Check for continuity on
each
wire between
the
ECM connector
and
main
harness
side meter
connector in the same wire color
terminals.
Is
there
continuity?
NO
- Open in wire
between the
ECM and
combination meter
YES
- GO TO STEP 7.