Making The 200-240 Vac Power Supply Cable - Omron Viper 650 User Manual

Robot with ethercat
Hide thumbs Also See for Viper 650:
Table of Contents

Advertisement

Making the 200-240 VAC Power Supply Cable

Use the following procedure to make the 200-240 VAC power supply cable.
Before you begin, you will need 3-wire, 0.8 mm
the AC power source to the eCS-ECAT interface panel.
1. Locate the AC power supply connector.
2. Unscrew the shell screw, open the connector, and remove the cover.
3. Loosen the two screws on the cable clamp.
4. Strip 18 to 24 mm of insulation from each of the three wires.
5. Insert the wires into the connector through the removable bushing.
6. Connect each wire to the correct terminal screw and tighten the screw firmly.
7. Tighten the screws on the cable clamp, then reinstall the cover and tighten the screw.
8. Prepare the opposite end of the cable for connection to the facility AC power source.
78
Figure 4-14. AC Power Supply Connector
2
(18 AWG) cable long enough to reach from
Viper 650 and 850 Robot with EtherCAT
21861-000 Rev A