AC Power Supply Connector

The cable and accessory box that came with your system contains the AC power supply con-
nector. The supplied plug is internally labeled for the AC power connections (L, E, N).
Additional Information: Refer to Connector Specifications on page 124 for more
information.
21861-000 Rev A
Line
Neutral
200–240
VAC 20 A
Earth Ground
User-supplied
AC Power
Cable
Figure 4-12. Typical AC Power Installation with Single-Phase Supply
L1
(Line 1)
10 A Slow-blow Fuses
L2
200–240
L3
VAC
Earth Ground
User-supplied
AC Power
Cable
Figure 4-13. Single-Phase Load across L1 and L2 of a Three-Phase Supply
Viper 650 and 850 Robot with EtherCAT
Chapter 4: System Cable Installation
10 A
Slow-blow Fuse
E
N
L
eCS-ECAT
1Ø 200-240 VAC
200–240 VAC
E
N
L
eCS-ECAT
1Ø 200-240 VAC
77