Regenerative Option - Mitsubishi Electric MDS-D-SPJ3 Specification Manual

Table of Contents

Advertisement

5-4-2 Regenerative option

Confirm the regeneration resistor capacity and possibility of connecting with the drive unit. Refer to "7-2 Selection
of the regenerative resistor" for details on selecting an regenerative resistor.
The regenerative resistor generates heats, so wire and install the unit while taking care to safety. When using the
regenerative resistor, make sure that flammable matters, such as cables, do not contact the resistor, and provide
a cover on the machine so that dust or oil does not accumulate on the resistor and ignite.
(1) Combination with servo drive unit
Corresponding
Standard built-in
servo drive unit
regenerative resistor
Parameter
setting value
Regenerative
capacity
MDS-D-SVJ3-03NA
10W
MDS-D-SVJ3-04NA
10W
MDS-D-SVJ3-07NA
20W
MDS-D-SVJ3-10NA
100W
MDS-D-SVJ3-20NA
100W
MDS-D-SVJ3-35NA
100W
Corresponding
Standard built-in
servo drive unit
regenerative resistor
Parameter
setting value
Regenerative
capacity
MDS-D-SVJ3-03NA
10W
MDS-D-SVJ3-04NA
10W
MDS-D-SVJ3-07NA
20W
MDS-D-SVJ3-10NA
100W
MDS-D-SVJ3-20NA
100W
MDS-D-SVJ3-35NA
100W
MR-RB032
MR-RB12
1200h
1300h
30W
100W
Resistance
40
40
value
100
100
40
13
9
9
FCUA-RB22
FCUA-RB37
2400h
155W
Resistance
40
value
100
100
40
13
9
9
MDS-D-SVJ3/SPJ3 Series Specifications Manual
External option regenerative resistor
MR-RB32
MR-RB30
GZG200W120
GZG200W3
OHMK
9OHMK
×3 units
×3 units
1400h
1500h
300W
300W
40
13
External option regenerative resistor
FCUA-RB55
R-UNIT2
2500h
2600h
2900h
185W
340W
25
20
5-4 Drive unit option
MR-RB50
MR-RB31
MR-RB51
GZG300W3
GZG200W2
GZG300W2
9OHMK
0OHMK
×3 units
×3 units
×3 units
1600h
1700h
500W
300W
13
6.7
FCUA-RB55
FCUA-RB75/2
2 units
2 units
connected in
connected in
parallel
parallel
2E00h
2D00h
700W
680W
15
10
0OHMK
1800h
500W
6.7
680W
15
5 - 33