Hard disk drives (HDD) and solid state drives (SSD)
7.4.3.4
Concluding steps
Ê Refer to the RAID documentation configuring the RAID, see
you need at hand" on page
7.4.4
Replacing a 2.5-inch HDD/SSD module
Customer Replaceable Unit
(CRU)
Tools: tool-less
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
●
currently being accessed. Observe the indicators on the HDD
module, as described in the operating manual of your server.
An HDD/SSD module can be replaced while the system is in
●
operation.
RAID configuration with a RAID controller:
Only RAID level 1, 1E, 10, 5, 50, 6 or 60 is allowed.
RAID configuration without a RAID controller:
Please follow the instruction provided separately.
All HDD/SSD modules (drives) must be uniquely identified so that
●
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.4.4.1
Preliminary steps
"Locating the defective server" on page 61
Ê
Ê Locate the defective HDD/SSD module as described in section
diagnostic indicators on the front" on page
Only applicable for removing intact HDD/SSD modules:
Ê Before removing a non-defective HDD/SSD module, put the drive into
"Offline" mode using your RAID configuration software.
200
46.
Upgrade and Maintenance Manual
Hardware: 5 minutes
63.
"Documents
"Local
RX2540 M2