Hard disk drives (HDD) and solid state drives (SSD)
7.4.3.4

Concluding steps

Ê Refer to the RAID documentation configuring the RAID, see
you need at hand" on page
7.4.4

Replacing a 2.5-inch HDD/SSD module

Customer Replaceable Unit
(CRU)
Tools: tool-less
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators on the HDD
module, as described in the operating manual of your server.
An HDD/SSD module can be replaced while the system is in
operation.
RAID configuration with a RAID controller:
Only RAID level 1, 1E, 10, 5, 50, 6 or 60 is allowed.
RAID configuration without a RAID controller:
Please follow the instruction provided separately.
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original mounting locations later. If this
is not done, existing data can be lost.
7.4.4.1

Preliminary steps

"Locating the defective server" on page 61
Ê
Ê Locate the defective HDD/SSD module as described in section
diagnostic indicators on the front" on page
Only applicable for removing intact HDD/SSD modules:
Ê Before removing a non-defective HDD/SSD module, put the drive into
"Offline" mode using your RAID configuration software.
200
46.
Upgrade and Maintenance Manual
Hardware: 5 minutes
63.
"Documents
"Local
RX2540 M2