6
Power supply unit (PSU)
Safety notes
V
CAUTION!
Do not disassemble the PSU. Doing so may cause electric shock.
●
Areas around the PSU may remain extremely hot after shutdown.
●
After shutting down the server, wait for hot components to cool down
before removing the PSU.
When installing a PSU, ensure that the connector of the PSU is not
●
damaged or bent.
Do not insert your hands in the PSU bay when removing the PSU.
●
Doing so may cause electric shock.
If the PSU is hard to remove, do not pull it out by force.
●
The PSU is heavy, so handle it carefully. If you drop it by mistake,
●
injuries may result.
For further safety information, please refer to chapter
●
information" on page
6.1
Basic information
AC PSU
The PRIMERGY RX2540 M2 server can be equipped with up to wo PSUs.
V
CAUTION!
The server is automatically set to a mains voltage in the range of:
– 100 V to 240 V, valid for Platinum 450 W and Platinum 800 W
– 200 V to 240 V, valid for Titanium 800 W
– 100 V to 120 V / 200 V to 240 V, valid for Platinum 1200 W
You may only operate the server if its rated voltage range corresponds to
the local mains voltage.
I
Power redundancy is possible with two PSUs. The effective power of the
PSUs may not differ.
RX2540 M2
49.
Upgrade and Maintenance Manual
"Important