Expansion cards and backup units
For GPGPU M60/P100
Figure 197: Inserting the second GPGPU
Ê Insert the completely prepared riser module.
I
Make sure that the riser module engages properly in the recesses
(see figure before).
Ê Carefully push down the riser module until the contacts of the riser card are
fully seated in the PCIe socket.
Ê Fasten the riser module with five screws.
Ê Connect the connector P2 of the power cable C38 to the GPGPU.
8.6.3.10 Installing the FBU riser module 2
Ê Install the second FBU as described in section
riser card holder" on page
302
291.
Upgrade and Maintenance Manual
"Installing the FBU on the