Processors - Fujitsu PRIMERGY RX2540 M2 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Basic software procedures
Ê Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
Using the command line interface (Linux only)
The memory error counter can be reset using the meclear utility which is part
of the ServerView agents for Linux.
I
meclear (Memory Module Error Counter Reset Utility) allows to reset
the error count collected for a memory module, for example after it has
been replaced.
For further details, please refer to the meclear manual pages.
Ê Log in as root.
Ê Enter the command below, followed by [ENTER]:
/usr/sbin/meclear
Ê Select the number of a memory module with a status other than "OK" or
"Not available".
Ê Repeat the step above until all memory modules show the "OK" status.
Ê Ensure that all pre-fail / fail status issues have been resolved in ServerView
Operations Manager.
5.2.7.2

Processors

ServerView Operations Manager may report a defective processor in case of a
critical error.
I
Important note
After replacing a defective CPU, the error counter must be reset
manually using one of the methods below.
Using ServerView Maintenance Tools (Windows only)
Ê Launch the ServerView Maintenance Tools:
– Windows Server 2008 R2 and below:
Start > (All) Programs > Fujitsu > ServerView Suite > Agents >
Maintenance Tools
– Windows Server 2012 and above:
Start > Apps > Fujitsu > Maintenance Tools
112
Upgrade and Maintenance Manual
RX2540 M2

Hide quick links: