Fujitsu PRIMERGY RX2540 M2 Upgrade And Maintenance Manual page 504

Table of Contents

Advertisement

Front panel and external front connectors
13.8.3.6 Concluding steps
"Installing the fan box" on page 399
Ê
"Reassembling" on page 73
Ê
"Connecting the power cord" on page 79
Ê
"Switching on the server" on page 82
Ê
"Resuming BitLocker functionality" on page 120
Ê
13.9
Front panel module on rack mounting
bracket
13.9.1 Replacing the front panel module on RMB
Field Replaceable Unit
(FRU)
Tools: Phillips PH1 / (+) No. 1screw driver
Note on system information backup / restore
I
The front panel module contains the Chassis ID EPROM that contains
system information like server name and model, housing type, serial
number and manufacturing data.
To avoid the loss of non-default settings when replacing the system
board, a backup copy of important system configuration data is
automatically stored from the system board NVRAM to the Chassis ID
EPROM. After replacing the system board the backup data is restored
from the Chassis ID board to the new system board.
V
CAUTION!
For that reason the front panel module and system board must not be
replaced simultaneously! In this case, restoring the system configuration
data on the system board would fail.
504
Upgrade and Maintenance Manual
Hardware: 10 minutes
Software: 5 minutes
RX2540 M2