Deleting The Flash Code Output And The Error Memory - KAMAZ 5490 Operation Manual

Table of Contents

Advertisement

Flash Code Output
3.7 Deleting the Flash Code Output and the Error
Memory
The flash code output (error number) and error memory
deletion can be triggered via the brake step lever. The flash
code is output by the Intarder check display.
Prompting of flash code output
Example for 5-stage braking step lever.
1. Switch ignition off.
2. Set braking step lever to a stage below the max, braking
step, here position 4.
3. Switch on ignition and wait for continuous light
(3 seconds) or flashing (5 seconds) of the Intarder check
display.
Example error number 23
Lamp test
ON
OFF
3
019638_en
6085 758 102b - 2006-10
Double-figure point
5
1
1
1
4. Within 5 seconds time, the braking step lever is set to
two stages below the max. braking step (here, position
3) and subsequently again to the position of one stage
below the max. braking step (here, position 4).
5. Wait for flash code output (also refer to: "Intarder check
display functions").
In addition to the normal functions, the Intarder check
display outputs the flash code (error number).
If the flash code output is triggered via the braking step
lever, then, upon completion of the lamp tests and/or after
conclusion of the 5-second-term flashing (in case of error),
the error numbers saved to the error memory are output in
the respective order.
Single-figure point
1
1
3
. . .
2
2
22
5
t s

Hide quick links: