KAMAZ 5490 Operation Manual page 217

Table of Contents

Advertisement

Pramotronic
(Copy)
ELTRA
TERMO OPEN JOINT STOCK COMPANY
«ELTRA TERMO»
1 Introduction
This instruction manual (IM) is assigned for study
of the structure, operation, assembly and regular
maintenance of the heater «PRAMOTRONIC 16WD24»
(further referred to as the heater).
The diesel heater of 16WD24.8106.000 model
with the nominal voltage 24V is designated for pre-
starting heat and automatic keeping of thermal conditions
of а liquid cooling diesel motor for all makes of trucks,
as well as for heating and automatic keeping of
temperature in a cabin (а passenger compartment) of
motor vehicles, buses and stationary premises at ambient
air temperature up to -45 °С.
The reliable operation of the heater and a long
term of its maintenance can be guaranteed only by
following all the rules and instructions stated in this
instruction manual.
Production Company
2 Technical characteristics of the heater
The characteristics in Chart 1 are given under the
ambient air temperature +20 °С and the nominal voltage.
Admissible fluctuations are ±10 %.
Items of characteristics
Nominal Voltage, V
Fuel
Diesel oil under State Standard Specification 305 (GOST 305)
Admissible voltage, V
Heating efficiency in operating mode:
Full mode , kilowatt
Medium mode, kilowatt
Low mode, kilowatt
Consume power (without electric pump), watt:
At start up (not more than)
In full operating mode
In medium operating mode
In low operating mode
Fuel consumption in operating mode:
Full mode , litre per hour
Medium mode, litre per hour
Low mode, litre per hour
Heat carrier
Admissible maximum heat carrier
pressure, kg/cm
Temprerature range set
control
panel
for
automatically in the cabin, C
The exhaust temperature,ºС (not more than) 500
Start up and stop action conditions
The heater operation time
Weight (of the set) kg (not more than)
1
Heater PRAMOTRONIC-16WD24
24
20...30
16±1,6
10
5
95
130
75
36
Kbnh
2,25
1,25
0,625
Tosol, antifreeze
2,5
on the
От 15 до 30
keeping
Manual
Not limited (is limited only by the
condition of the electric power storage)
9
Chart 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents