7.2.6 Contact closure

The MSD has a total of nine (9) independently controlled contact closure channels for external control.
Each connector supports three (3) channels. The maximum load for each contact is 24 VDC @ 500 mA.
Connect a cable to the 6-pin terminal block, and then insert into the appropriate connector on the MSD's rear
panel.
AWG28 to AWG16 conductor gauge is recommended. The recommended wire strip length is 0.28 in. (7 mm).
28
[Fig. 7.6] Connecting cable to 6-pin terminal block connector
Up to 0.28" (7mm)