P24-IN Module's DC 24V receiving terminal
● Connect +24V (or 12V) power supply to the receiving terminal.
● Match the connection polarity to the one indicated on the plug (24/G).
● Recommended wire material: AWG20 - 18 (0.5 to 0.9mm
● For fixing cables: Crimp tool YC-630 (JST)
Board-side post: B2PS-VH

3.6.5 Connector Terminal Electrical Requirements

The following table shows the electrical requirements of connector signals described in the table above.
DIO 16/16 connector
Total of all EXTPOW
terminals
Per input
Per signal output
A. Post

Figure 3.6-3 Receiving terminal wiring

IN/
OUT
O
Allowable current: 1.6A or less
I
Consumption current: 8mA/point or less
Allowable current: 80mA/point or less
O
(However, total of 8 points must be 500mA or less.)
Table 3.6-4 Connector terminal electrical requirements
2
stranded wire)
Housing: VHR-2N
Contact: BVH-41T-P1.1
B. Housing (Fixed to the contact)