Communication Module Hm-Gn00G; Specifications; External Appearance; Figure 3.2-1 External Appearance Of Hm-Gn00G Communication Module - Hivertec motionCAT Series User Manual

Motion network system
Table of Contents

Advertisement

3.2 Communication Module HM-GN00G

There must always be one HM-GN00G communication module per HMG type slave to send and receive
Motionnet communication, and relay communication data to modules stacked within the same slave or other
slaves.
Refer to "2.4 HM-GU00G" for the communication module of HUG base slaves.

3.2.1 Specifications

Category
ASIC for Motionnet control
Communication data relay
Basic
specification
Number of modules that can
be stacked
Safety feature Overcurrent protection
Power supply
Consumption current
Environment
Temperature requirement
requirements
Module dimensions
(Excluding the connector's
projecting part)

3.2.2 External Appearance

Cyclic
communication
indicator

Figure 3.2-1 External appearance of HM-GN00G communication module

Item
None
Relays communication data of one line to the next slave
0 to 6
This is the number of modules that can be directly
stacked on this device for use
A PTC thermistor (poly switch) cuts the current when the
current flowing through its receiving terminal exceeds a
certain amount.
DC +12V to DC +24V
Max
Typical
0 to 50 degrees Celsius without dew condensation
Module: Depth 85mm × Height 105mm
Outer dimensions of the frame: Depth 110mm × Height 115mm × Width 14.2mm
Table 3.2-1 HM-GN00G communication module specifications
C
C
Specifications
Connector for Motionnet
communication (J1)
Connector for Motionnet
communication (J2)
Rotary switch for module ID setting
Communication settings switch
Communication module POW ON indicator
Module's receiving terminal (P24-IN)