A Module Hm-A4401C (4-In/4-Out Voltage-Type Analog Module); Figure 6.4-24 A Module Operation Screen; Figure 6.4-25 Detailed A Module Operation Screen - Hivertec motionCAT Series User Manual

Motion network system
Table of Contents

Advertisement

6.4.12 A Module
The following operation screen displays when A4401(A) is selected on the TreeView.
(1)
Functions
⚫ Display the analog voltage input to the specified A module (A/D CH 1-4 input value)
⚫ Display the analog voltage output from the specified A module (D/A CH 1-4 output value)
⚫ Set the analog voltage value to be output from the specified A module (D/A CH 1-4 output value
setting)
(2)
A module operation screen
HM-A4401C (4-In/4-Out Voltage-type Analog Module)

Figure 6.4-24 A module operation screen

D/A output value of each CH (Unit: V)

Figure 6.4-25 Detailed A module operation screen

A/D input value of each CH (Unit: V)
131
Set D/A output value for each CH
(Unit: V)
D/A output button of each CH

Advertisement