2.2.3 Board Settings
The following diagram shows HCPCI-MNT720M settings to be configured. Configure the board ID and
communication speed settings.
Line2
Line1
Di4/Do4
(1)
Board ID setting
When using two or more motionCAT master boards, each must be configured with a different ID.
Changing the setting is unnecessary when using only one board.
(2)
Communication setting
If communication errors occur frequently due to the installation environment etc, use a lower
communication speed. Make sure that each slave to connect is also configured with the same
communication speed. Normally, this setting does not need to be changed.
SPD0 SPD1
2.5Mbps
ON
ON
5Mbps
OFF
ON
SW1
10Mbps
ON
OFF
20Mbps
OFF
OFF
Figure 2.2-2 Setting positions
8
BDID
Figure 2.2-3 Rotary DIP switch for board ID setting
SPD0 SPD1
2.5Mbps
ON
ON
5Mbps
OFF
ON
10Mbps
ON
OFF
20Mbps
OFF
OFF
Figure 2.2-4 Communication speed setting switch
24
8
BDID
Rotary DIP switch for board
ID setting
SW1
Communication
speed switch